Problem description: Abnormal detection of FAX control PWB incompatibility in the initial communication with the FAX control PWB, any normal communication command is not transmitted
Problem description: An abnormal status is output from the flash memory
Step
Description
Causes
Measures
1
Resetting the main power
The flash memory does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Checking the main PWB
The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty
Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB
Problem description: The reading or writing into the flash memory is unavailable
Step
Description
Causes
Measures
1
Resetting the main power
The flash memory does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Checking the main PWB
The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty
Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB
Problem description: The flash memory data read at the initial start-up is faulty
Step
Description
Causes
Measures
1
Resetting the main power
The flash memory does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Checking the main PWB
The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty
Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB
Problem description: 1. Continuous five times detection of no response from the device for 5ms or more on reading / writing 2. Data read twice do not match continuous 8 times 3. Writing data and reading data do not match continuous 8 times
Step
Description
Causes
Measures
1
Resetting the main power
The EEPROM on the engine PWB does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Checking the EEPROM on the engine PWB
The EEPROM is not properly attached
Reattach the EEPROM on the engine PWB
3
Replacing the EEPROM
The EEPROM is faulty
1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary.
Problem description: The data read from the EEPROM is judged as abnormal
Step
Description
Causes
Measures
1
Resetting the main power
The EEPROM on the engine PWB does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Executing U021
The storage data in the EEPROM on the engine PWB is faulty
Execute U021
3
Replacing the EEPROM
The EEPROM is faulty
1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary.
Problem description: 1. Errors are detected in both backup memory of the engine PWB charge counter and main PWB charge counter. 2. Main PWB counter data and engine PWB counter date are faulty
Step
Description
Causes
Measures
1
Replacing the main PWB
The main PWB is faulty
Replace the main PWB and execute U004
2
Replacing the EEPROM on the engine PWB
The EEPROM is faulty
1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary
Problem description: The machine serial Nos. in the main PWB and the EEPROM on the engine PWB mismatch when turning the power on
Step
Description
Causes
Measures
1
Checking the machine serial No. of the main PWB
The main PWB for the different main unit is installed
Check the machine serial Nos of MAIN and ENGINE at U004, and install the correct main PWB if the MAIN No. differs
2
Checking the machine serial No. in the EEPROM on the engine PWB
The EEPROM for the different main unit is installed
Check the machine serial Nos of MAIN and ENGINE at U004, and install the correct EEPROM on the engine PWB if the ENGINE machine serial No. differs
3
Replacing the main PWB
The main PWB is faulty
When the MAIN machine serial No. differs at U004, replace the main PWB and execute U004
4
Checking the EEPROM on the engine PWB
The EEPROM is faulty
If the machine serial number on the engine PWB is different at U004, reattach the EEPROM. If not repaired, replace the EEPROM on the engine PWB by referring to the following procedures. 1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary.
Problem description: The print sequence jam (J010x) is detected 2 times continuously
Step
Description
Causes
Measures
1
Checking the image data
The image data is faulty
When this issue occurs only when handling the certain image data, check if the image data is faulty
2
Checking the situation
The printing operation of the certain file is faulty
Acquire the job's log if the phenomenon can be reproduced by specifying the job when the error was detected
3
Checking the main PWB
The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty
Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB
Problem description: The program stored in the flash memory on the FAX PWB is broken so it cannot perform
Step
Description
Causes
Measures
1
Resetting the main power
The FAX PWB is not connected properly
Turn off the power switch and pull out the power plug. After passing 5s, reattach the FAX PWB and reinsert the power plug. Then, turn on the power switch
Problem description: Data was not properly transmitted even if the specified times of retry were made when the large volume data is transmitted between the FAX PWB and the main PWB
Step
Description
Causes
Measures
1
Resetting the main power
The FAX PWB does not operate properly
Turn off the power switch and pull out the power plug. After passing 5s, reattach the FAX PWB and reinsert the power plug. Then, turn on the power switch
Problem description: The backup data could not be stored since the file system of the flash memory is faulty
Step
Description
Causes
Measures
1
Resetting the main power
The FAX PWB does not operate properly
Turn off the power switch and pull out the power plug. After passing 5s, reattach the FAX PWB and reinsert the power plug. Then, turn on the power switch
Problem description: • 24V power shutoff signal is detected 1s continuously. • Other service call error occurs after 24V power shutoff signal is lowered, and then 24V power is recovered
Step
Description
Causes
Measures
1
Resetting the main power
The firmware in the engine PWB does not operate normally
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Low-voltage PWB - Engine PWB
3
Replacing the low voltage PWB
The low voltage PWB is faulty
When the +24V generation from the low voltage PWB is not stable, and it lowers, replace the low voltage PWB
Problem description: • Cassette 1 lift motor over-current is detected 5 times continuously. • Lift sensor on is not detected 5 times continuously when passing 15s after cassette 1 is loaded
Step
Description
Causes
Measures
1
Checking the lift plate
The lift plate does not operate properly
Repair or replace the lift plate when it does not move vertically
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Lift motor - Engine PWB(YC15) • Lift sensor - Engine PWB(YC15)
3
Checking the lift motor
The lift motor is faulty
Check the lift motor operation, and replace it if necessary
4
Checking the lift sensor
The lift sensor is not properly attached, or it is faulty
Reattach PF lift upper limit sensor. If not repaired, replace it
Object: 500-sheet paper feeder, 500-sheet x2 paper feeder
Problem description: The PF lift sensor 1 on is not detected 5 times continuously when passing 15s after loading cassette 2
Step
Description
Causes
Measures
1
Checking the lift plate
The lift plate does not operate properly
Repair or replace the lift plate when it does not move vertically
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF lift moor 1 - PF PWB (YC4) • PF upper limit sensor 1 - PF PWB (YC3)
3
Checking PF lift motor 1
PF lift motor 1 is faulty
Check the operation of lift motor 1, and replace it if necessary
4
Checking PF lift sensor 1
PF lift sensor 1 is not properly attached, or it is faulty
Reattach PF lift sensor 1. If not repaired, replace it
Problem description: The PF lift sensor 2 on is not detected 5 times continuously when passing 15s after loading cassette 3
Step
Description
Causes
Measures
1
Checking the lift plate
The lift plate does not operate properly
Repair or replace the lift plate when it does not move vertically
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF lift moor 2 - PF PWB (YC6) • PF upper limit sensor 2 - PF PWB (YC5)
3
Checking PF lift motor 2
PF lift motor 2 is faulty
Check the operation of lift motor 2, and replace it if necessary
4
Checking PF lift sensor 2
PF lift sensor 2 is not properly attached, or it is faulty
Reattach PF lift sensor 2. If not repaired, replace it
Object: 500-sheet paper feeder, 500-sheet x2 paper feeder
Problem description: The communication error was detected 10 times continuously
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Engine PWB (YC25) - PF PWB(YC1)
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware and PF firmware to the latest version
Object: 500-sheet paper feeder, 500-sheet x2 paper feeder For internal count
Problem description: The writing data and the reading data mismatch 4 times continuously when writing
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Engine PWB (YC25) - PF PWB(YC1)
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware and PF firmware to the latest version
Problem description: Developer motor K steady state off is detected for 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer motor K - Engine PWB (YC18)
3
Checking the drive unit
The drive unit is faulty
Execute U030 [Dlp(K)/Drum] and check the developer motor K operation. If there are any load for the gear rotation inside the drive unit replace drive unit B
Problem description: Developer motor CMY steady state off is detected 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer motor CMY - Engine PWB (YC19)
3
Checking the drive unit
The drive unit is faulty
Execute U030 [Dlp(Col)] and check the drum motor CMY operation. If there are any load for the gear rotation inside the drive unit replace drive unit A
Problem description: Drum motor K steady state off is detected for 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drum motor K - Engine PWB (YC19)
3
Checking the drive unit
The drive unit is faulty
Execute U030 [Dlp(K)/Drum] and check the drum motor K operation. If there are any load for the gear rotation inside the drive unit replace drive unit A
Problem description: Drum motor CMY steady state off is detected 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drum motor CMY - Engine PWB (YC19)
3
Checking the drive unit
The drive unit is faulty
Execute U030 [Dlp(K)/Drum] and check the drum motor CMY operation. If there are any load for the gear rotation inside the drive unit replace drive unit A
Problem description: The fuser motor steady state off is detected 1s continuously after becoming steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser motor - Engine PWB (YC18)
3
Checking the drive unit
The drive unit is faulty
Check the fuser motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit B
Problem description: The fuser motor is not in the steady state within 1.5s after start-up
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser motor - Engine PWB (YC18)
3
Checking the drive unit
The drive unit is faulty
Check the fuser motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit B
Problem description: The conveying motor steady state off is detected 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Conveying motor - Engine PWB (YC14)
3
Checking the drive unit
The drive unit is faulty
Execute U030 [Feed] and check the feed motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit C
Problem description: The conveying motor is not in the steady state within 2s after start-up
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Conveying motor - Engine PWB (YC14)
3
Checking the drive unit
The drive unit is faulty
Execute U030 [Feed] and check the feed motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit C
Object: 500-sheet paper feeder, 500-sheet x2 paper feeder
Problem description: An error signal was detected 2s continuously during the PF motor drive
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF motor - PF PWB(YC25)
Problem description: The error signal is detected for 3s continuously after the belt release motor starts up
Step
Description
Causes
Measures
1
Firmware upgrade
The engine firmware is faulty
Upgrade the engine firmware to the latest version
2
Checking the drive parts
The drive transmission of the belt release motor is faulty
Repair the drive transmission parts if the drive from the belt release motor is not transmitted
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Belt release motor - Transfer PWB (YC2) • Belt rotation sensor - Transfer PWB (YC2) • Transfer PWB (YC2) - Transfer relay PWB (YC1) • Transfer relay PWB (YC2) - Engine PWB (YC11)
4
Checking the belt rotation sensor
The belt rotation sensor comes off
Reattach or replace the belt rotation sensor
5
Checking the belt release motor
The belt release motor is not operated correctly
Reattach or replace the belt release motor
6
Primary transfer unit replacement
The primary transfer roller lift-up drive section is faulty
Problem description: The home position sensor is off and does not turn on when passing the specified time at initialization and it does not turn on at retry once
Step
Description
Causes
Measures
1
Unlocking the primary mirror unit
The primary mirror unit is not unlocked
Unlock the primary mirror unit
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
3
Checking the scanner and scanner wire
A load is applied to the scanner movement
Move the mirror unit manually. If there is heavy load in excess, clean the scanner wire, wire drum, scanner rail, etc
4
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Scanner motor - Engine PWB (YC12)
5
Checking the scanner motor and the belt tension
The scanner motor or belt tension is faulty
Reattach the scanner motor and adjust the belt tension. If not repaired, replace the scanner motor
6
Checking the home position sensor
The home position sensor is faulty
Reattach the home position sensor. If not repaired, replace it
Problem description: The home position sensor is off and does not turn on when passing the specified time at initialization and it does not turn on at retry once
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the scanner and ISU shaft
A load is applied to the scanner movement
Move the mirror unit manually. If there is heavy load in excess, check the drive belt and clean the ISU shaft
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Scanner motor - Engine PWB (YC12)
4
Checking the scanner motor
The scanner motor is faulty
Reattach the scanner motor. If not repaired, replace it
5
Checking the home position sensor
The home position sensor is faulty
Reattach the home position sensor. If not repaired, replace it
Problem description: The white reference data retrieved by lighting the lamp at the initial operation is at the specified value or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the LED lamp
The LED lamp does not light
Check if the LED lamp lights. If it does not light, replace the lamp unit and execute U411 [Table].
3
Checking the connection
FFC is not connected properly. Or it is faulty
Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • LED drive PWB - Main PWB (YC3003)
4
Checking the lens unit
The CCD PWB is faulty
Clean the FFC terminal and reconnect it. If deformed or broken, replace the FFC. • CCD PWB - Main PWB (YC3002) If not repaired, replace the lens unit and execute U411
Problem description: • The white reference data retrieved by lighting the lamp at the initial operation is lower than the specified value. • The white reference data retrieved by lighting the lamp at the auto table adjustment is lower than the specified value.
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the CIS lamp
The CIS lamp does not light
Check if the CIS lamp turns on. If not, replace the lamp unit and execute U411 [Table]
3
Checking the connection
FFC is not connected properly. Or it is faulty
Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • CIS PWB - Main PWB (YC3001)
Problem description: The white reference data after adjustment is not within the target range
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Cleaning the backside of the contact glass
The white reference sheet is dirty
Clean the white reference sheet at the backside of the contact glass
3
Checking the LED lamp
The LED lamp is broken
Check if the LED lamp lights. If it does not light, replace the lamp unit and execute U411 [Table]
4
Checking the connection
FFC is not connected properly. Or it is faulty
Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • LED drive PWB - Main PWB (YC3003)
5
Checking the lens unit
The CCD PWB is faulty
Clean the FFC terminal and reconnect it. If deformed or broken, replace the FFC. • CCD PWB - Main PWB (YC3002) If not repaired, replace the lens unit and execute U411
Problem description: The white reference data after adjustment is not within the target range
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Cleaning the backside of the contact glass
The white reference sheet is dirty
Clean the white reference sheet at the backside of the contact glass
3
Checking the CIS lamp
The CIS lamp does not light
Check if the CIS lamp turns on. If not, replace the lamp unit and execute U411 [Table]
4
Checking the connection
FFC is not connected properly. Or it is faulty
Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • CIS PWB - Main PWB (YC3001)
Problem description: Readback values are different 4 times continuously during communication between the scanner and ASIC
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the main firmware and the engine firmware to the latest version
2
Checking the connection
FFC is not connected properly. Or it is faulty
Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • Main PWB (YC26) - Engine PWB (YC3)
Problem description: • Mail box buffer overflow is detected. • Software sequence error is detected.
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the main firmware and the engine firmware to the latest version
2
Executing U021
The memory operation is faulty
Execute U021 and initialize the backup data
3
Checking the connection
FFC is not connected properly. Or it is faulty
Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • Main PWB (YC26) - Engine PWB (YC3)
Problem description: Polygon motor K is not in the steady state within 10s after becoming steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor K - LSU relay PWB (YC5) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU K if it does not rotate properly
Problem description: Polygon motor C is not in the steady state within 10s after becoming steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor C - LSU relay PWB (YC7) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU C if it does not rotate properly
Problem description: Polygon motor M is not in the steady state within 10s after becoming steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor M - LSU relay PWB (YC6) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU M if it does not rotate properly
Problem description: Polygon motor Y is not in the steady state within 10s after becoming steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor Y - LSU relay PWB (YC8) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU Y if it does not rotate properly
Problem description: Polygon motor K is off from the steady state for 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor K - LSU relay PWB (YC5) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU K if it does not rotate properly
Problem description: Polygon motor C is off from the steady state for 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor C - LSU relay PWB (YC7) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU C if it does not rotate properly
Problem description: Polygon motor M is off from the steady state for 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor M - LSU relay PWB (YC6) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU M if it does not rotate properly
Problem description: Polygon motor Y is off from the steady state for 1s continuously after becoming the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor Y - LSU relay PWB (YC8) • LSU relay PWB (YC9) - Engine PWB (YC6)
3
Checking the polygon motor
The polygon motor does not rotate properly
Check the rotation sound of the polygon motor, and reattach or replace LSU Y if it does not rotate properly
Problem description: BD is not detected within 1s after polygon motor K is in the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the main firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB K - LSU relay PWB (YC1) • LSU relay PWB (YC10) - Main PWB (YC23)
Problem description: BD is not detected within 1s after polygon motor C is in the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the main firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB C - LSU relay PWB (YC3) • LSU relay PWB (YC10) - Main PWB (YC23)
Problem description: BD is not detected within 1s after polygon motor M is in the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the main firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB M - LSU relay PWB (YC2) • LSU relay PWB (YC10) - Main PWB (YC23)
Problem description: BD is not detected within 1s after polygon motor Y is in the steady state
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the main firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB Y - LSU relay PWB (YC4) • LSU relay PWB (YC10) - Main PWB (YC23)
Problem description: The error signal is detected for 2s continuously after the motor starts up
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the drive parts
The drive transmission from the LSU cleaning motor is faulty
Repair the drive transmission parts if the drive from the LSU cleaning motor is not transmitted
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU cleaning motor - LSU relay PWB (YC11) • LSU relay PWB (YC9) - Engine PWB (YC6)
Problem description: Writing data and reading data does not match 8 consecutive times
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the main firmware and engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Main PWB (YC26) - Engine PWB (YC3)
Problem description: 1. The fuser center thermistor does not detect 100°C / 212°F or more within 25s after warm-up is started 2. During the warm-up, the fuser center thermistor does not detect the ready temperature within 20s after it detects 100°C / 212°F
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Executing U169
The IH setting mismatches the power supply specification
Set the destination same as the voltage of the IH PWB at U169
3
Removing foreign material
There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt
Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit
4
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
5
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9) • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
6
Replacing the fuser unit
The parts such as the thermistor or thermal cutout are faulty
C6020: Fuser center thermistor high temperature error
Problem description: The fuser center thermistor detected 230°C / 446°F or more for 1s
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9) • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
Problem description: 1. During warm-up, the fuser center thermistor detects 41°C / 105°F for 1s continuously while the fuser edge thermistor detects 100°C / 212°F or more 2. The fuser center thermistor does not detect 25°C / 77°F within 12s after start-up
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Removing foreign material
There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt
Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit
3
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
4
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9) • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
C6050: Fuser center thermistor low temperature error
Problem description: The fuser center thermistor detects less than 80°C / 176°F for 1s during printing
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Removing foreign material
There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt
Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit
3
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
4
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9) • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
C6120: Fuser press roller thermistor high temperature error
Problem description: The fuser press roller thermistor detected 210°C / 410°F or more for 1s
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9)
Problem description: 1. During warm-up, the fuser press roller thermistor detects less than 35°C / 95°F for 60s continuously 2. After finishing warm-up, the fuser press roller thermistor detects less than 35°C / 95°F for 30s continuously
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Removing foreign material
There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt
Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit
3
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
4
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9) • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
Problem description: After warm-up is started, the fuser edge thermistor does not detect 80°C / 176°F within 25s. Or, during the warm-up, specified temperature (Ready display temperature) is not detected even 420s passed after center thermistor reached 100°C / 212°F
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Removing foreign material
There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt
Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit
3
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
4
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9) • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
C6220: Fuser edge thermistor high temperature error
Problem description: The fuser edge thermistor detects 245°C / 473°F or more for 1s
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9)
C6230: Fuser edge thermistor high temperature error
Problem description: 1. During warm-up, the fuser edge thermistor detects less than 41°C / 105°F for 1s continuously while the fuser center thermistor detects 100°C / 212°F or more 2. The fuser edge thermistor does not detect 25°C / 77°F within 12s after start-up
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9)
C6250: Fuser edge thermistor low temperature error
Problem description: The fuser edge thermistor detected less than 80°C / 176°F for 1s during printing
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Removing foreign material
There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt
Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit
3
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
4
Checking the connection
The parts such as the thermistor are faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9) • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
5
Replacing the fuser unit
The parts such as the thermistor or thermal cutout are faulty
C6320: Fuser middle thermistor high temperature error
Problem description: The fuser middle thermistor detected 245°C / 473°F or more for 1s
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9)
Problem description: The fuser middle thermistor detects less than 41 °C / 105°F for 1s continuously while the fuser center thermistor or the fuser edge thermistor detects 100°C / 212°F or more during warm-up
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9)
Problem description: The belt rotation pulse is not input for 1.8s continuously
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9)
4
Replacing the fuser unit
The fuser unit parts such as the fuser heat belt, the belt rotation detecting system, or the belt rotation sensor are faulty
Problem description: 1. The fuser pressure release sensor does not turn off even after 10s passed from instructing to reduce the fuser pressure 2. The fuser pressure release sensor does not turn on even after 10s passed from instructing to increase the fuser pressure 3. The lock signal of the fuser pressure release motor became error for 300ms
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit - Engine PWB (YC9)
4
Replacing the fuser unit
The fuser unit is faulty at the fuser pressure release mechanism or the fuser pressure release sensor
Problem description: The IGBT temperature acquired from the power microprocessor detects 115°C / 239°F or more for 1s continuously
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH fan motor - Engine PWB (YC20) • IH PWB (YC4) - Engine PWB (YC10)
C6760: Fuser IH input excessive electric current error
Problem description: The input current obtained from the power microcomputer was 20A (100/120V) or 10A (200V) or more continued for 200ms
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the fuser unit
The fuser heat belt is faulty
Detach the fuser unit and check if the fuser heat belt is not faulty. If there is any damage, replace the fuser unit
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH PWB (YC4) - Engine PWB (YC10)
Problem description: After fuser heating starts,the electric power detection on the IH PWB detected a set electric power value of 30% or less for a predetermined time
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the fuser unit
There are foreign objects in the drawer contact terminal of the fuser unit
Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH unit - IH PWB (YC2, YC3) • IH PWB (YC4) - Engine PWB (YC10)
Problem description: Lock-up is detected for 20s continuously when the fan motor drives
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH fan motor - Engine PWB (YC20)
3
Checking the IH fan motor
The IH fan motors do not properly operate
Clean the IH fan motor and remove foreign objects. If not resolved after that, replace the IH fan motor
Problem description: 1. Communication between the IH PWB and the engine PWB is not established in the initial communication. (150ms interval x 10 times retries and then 3 times retries of the relay remote) 2. After the initial communication is established, communication between the IH PWB and the engine PWB is not established at the operation except for printing. (If communication fails for 500ms, 3 times retries or the relay remote are performed) 3. After the initial communication is established, communication between the IH PWB and the engine PWB is not established durint printing. (If communication fails for 500ms, 150ms interval x 10 times retries are performed)
Step
Description
Causes
Measures
1
Resetting the main power
The power startup delays
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH PWB (YC4) - Engine PWB (YC10)
Problem description: The engine backup data does not match the IH PWB power supply destination. (0, 5 or more)
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Executing U169
The voltage setting at U169 mismatches the voltage of the IH PWB
Set the destination same as the voltage of the IH PWB at U169
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH PWB (YC4) - Engine PWB (YC10)
Problem description: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the developer unit
The developer unit is not properly installed
Reinstall developer unit K so that the connector firmly connects
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB K - Drum/Developer relay PWB (YC9) • Drum/Developer relay PWB (YC1) - Engine PWB (YC17)
Problem description: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the developer unit
The developer unit is not properly installed
Reinstall developer unit C so that the connector firmly connects
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB C - Drum/Developer relay PWB (YC7) • Drum/Developer relay PWB (YC1) - Engine PWB (YC17)
Problem description: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the developer unit
The developer unit is not properly installed
Reinstall developer unit M so that the connector firmly connects
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB M - Drum/Developer relay PWB (YC8) • Drum/Developer relay PWB (YC1) - Engine PWB (YC17)
Problem description: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the developer unit
The developer unit is not properly installed
Reinstall developer unit Y so that the connector firmly connects
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB Y - Drum/Developer relay PWB (YC6) • Drum/Developer relay PWB (YC1) - Engine PWB (YC17)
Problem description: The sensor input data is 0.3V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the developer unit
The developer unit is not properly installed
Reinstall developer unit K so that the connector firmly connects
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB K - Drum/Developer relay PWB (YC9) • Drum/Developer relay PWB (YC1) - Engine PWB (YC17)
Problem description: The sensor input data is 3.0V or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Reinstalling the developer unit
The developer unit is not properly installed
Reinstall developer unit K so that the connector firmly connects
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB K - Drum/Developer relay PWB (YC9) • Drum/Developer relay PWB (YC1) - Engine PWB (YC17)
Problem description: The sensor input data is 0.3V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector or FFC is not properly connected, or the wire or FFC is faulty
Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB K - LSU relay PWB (YC1) • LSU relay PWB (YC9) - Engine PWB(YC6)
Problem description: The sensor input data is 0.3V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector or FFC is not properly connected, or the wire or FFC is faulty
Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB Y - LSU relay PWB (YC4) • LSU relay PWB (YC9) - Engine PWB(YC6)
Problem description: The sensor input data is 3.0V or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector or FFC is not properly connected, or the wire or FFC is faulty
Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB K - LSU relay PWB (YC1) • LSU relay PWB (YC9) - Engine PWB(YC6)
Problem description: The sensor input data is 3.0V or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector or FFC is not properly connected, or the wire or FFC is faulty
Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB Y - LSU relay PWB (YC4) • LSU relay PWB (YC9) - Engine PWB(YC6)
Problem description: The sensor input data is 0.3V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Container relay PWB (YC1) - Engine PWB (YC22)
Problem description: The sensor input data is 3.0V or more
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Container relay PWB (YC1) - Engine PWB (YC22)
Problem description: • The sensor output value of the dark potential is 0.15V or less, or 0.80V or more • Bright potential is lower than the dark potential, or the gap is 0.5V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Cleaning the front ID sensor
The front ID sensor is dirty
Clean the front ID sensor surface
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor - Engine PWB (YC7)
Problem description: • The sensor output value of the dark potential is 0.15V or less, or 0.80V or more. • Bright potential is lower than the dark potential, or the gap is 0.5V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Cleaning the rear ID sensor
The rear ID sensor is dirty
Clean the rear ID sensor surface
3
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Rear ID sensor - Engine PWB (YC7)
Problem description: The density of the BK-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment
Step
Description
Causes
Measures
1
Resetting the main power
The ID sensor does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
3
Cleaning the ID sensor
The ID sensor is dirty
Clean the surface of the front and rear ID sensors
4
Checking the developer unit and drum unit
The developer unit or the drum unit is not properly installed
Reinstall developer unit K and drum unit K
5
Checking the primary transfer unit
The primary transfer belt is dirty
Clean the surface of the primary transfer belt, or replace the primary transfer unit
6
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor -Engine PWB (YC7)
Problem description: The density of the C-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment
Step
Description
Causes
Measures
1
Resetting the main power
The ID sensor does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
3
Cleaning the ID sensor
The ID sensor is dirty
Clean the surface of the front and rear ID sensors
4
Checking the developer unit and drum unit
The developer unit or the drum unit is not properly installed
Reinstall developer unit C and drum unit C
5
Checking the primary transfer unit
The primary transfer belt is dirty
Clean the surface of the primary transfer belt, or replace the primary transfer unit
6
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor -Engine PWB (YC7)
Problem description: The density of the M-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment
Step
Description
Causes
Measures
1
Resetting the main power
The ID sensor does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
3
Cleaning the ID sensor
The ID sensor is dirty
Clean the surface of the front and rear ID sensors
4
Checking the developer unit and drum unit
The developer unit or the drum unit is not properly installed
Reinstall developer unit M and drum unit M
5
Checking the primary transfer unit
The primary transfer belt is dirty
Clean the surface of the primary transfer belt, or replace the primary transfer unit
6
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor -Engine PWB (YC7)
Problem description: The density of the Y-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment
Step
Description
Causes
Measures
1
Resetting the main power
The ID sensor does not operate properly
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
3
Cleaning the ID sensor
The ID sensor is dirty
Clean the surface of the front and rear ID sensors
4
Checking the developer unit and drum unit
The developer unit or the drum unit is not properly installed
Reinstall developer unit Y and drum unit Y
5
Checking the primary transfer unit
The primary transfer belt is dirty
Clean the surface of the primary transfer belt, or replace the primary transfer unit
6
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor -Engine PWB (YC7)
Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch
2
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
3
Cleaning the ID sensor
The ID sensor is dirty
Clean the surface of the front and rear ID sensors
4
Checking the developer unit and drum unit
The developer unit or the drum unit is not properly installed
Reinstall the developer unit and drum unit
5
Checking the primary transfer unit
The primary transfer belt is dirty
Clean the surface of the primary transfer belt, or replace the primary transfer unit
6
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor -Engine PWB (YC7)
Problem description: The sensor input data is 0.3V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Temperature/humidity sensor - Engine PWB (YC11)
Problem description: The sensor input data is 0.3V or less
Step
Description
Causes
Measures
1
Firmware upgrade
The firmware is not the latest version
Upgrade the engine firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Temperature/humidity sensor - Engine PWB (YC11)
Problem description: The DF tray upper limit sensor on is detected when the DF tray motor is in ascending operation
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF tray upper limit sensor - DFPWB (CN5) • Paper level sensor 1, 2 - DFPWB (CN6)
2
Replacing the sensor
The Dr tray upper limit sensor, paper level sensor 1 or 2 is faulty
Replace the DF tray upper limit sensor or paper level sensor
Problem description: The DF belt sensor on or off cannot be detected when passing the specified time after the DF belt solenoid turns on
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the wire connector terminal and reconnect it. If there is no continuity, replace the wire. • DF belt sensor - DF PWB (CN10) • DF belt solenoid - DF PWB (CN21)
Problem description: During the DF tray motor drive, the DF tray lower limit sensor, paper level sensor 1 and 2 on is not detected within 10s
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF tray motor - DF PWB (CN15) • DF tray lower limit sensor - DF PWB (CN5) • Paper level sensor1, 2 - DF PWB (CN6)
2
Replacing the DF tray motor
The DF tray motor is faulty
Replace the DF tray motor
3
Replacing the sensor
The DF tray lower limit sensor, paper level sensor 1 or 2 is faulty
Replace the DF tray lower limit sensor or paper level sensor
Problem description: The DF adjustor sensor 2 on or off cannot be detected when passing the specified time after the DF adjustor motor 2 turns on
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF adjustor motor 2 - DFPWB (CN18) • DF adjustor sensor 2 - DFPWB (CN7)
Problem description: The DF adjustor sensor 1 on or off cannot be detected when passing the specified time after the DF adjustor motor 1 turns on
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF adjustor motor 1 - DFPWB(CN18) • DF adjustor sensor 1 - DFPWB(CN7)
Problem description: The DF roller sensor on or off cannot be detected when passing the specified time after the DF roller motor turns on
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF roller motor - DF PWB (CN20) • DF roller sensor - DF PWB (CN11)
Problem description: The DF slide sensor on or off cannot be detected when passing the specified time after the DF slide motor turns on
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF slide motor - DF PWB(CN14) • DF slide sensor - DF PWB(CN22)
Problem description: The communication error was detected 10 times continuously
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the wire connector terminal and reconnect it. If there is no continuity, replace the wire. • Engine PWB (YC5) - DF relay PWB (YC2) • DF relay PWB (YC3) - DF PWB (CN1)
Object: 500-sheet document finisher + relay conveying unit
Problem description: The communication error was detected 10 times continuously
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Engine PWB (YC5) - DF relay PWB (YC2) • DF relay PWB (YC4) - BR PWB (YC5)
Object: 500-sheet document finisher + relay conveying unit
Problem description: 1. Communication error occurs with either the finisher or relay conveying unit. 2. Communication error occurs while installation of the relay conveying unit is detected
Step
Description
Causes
Measures
1
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the wire connector terminal and reconnect it. If there is no continuity, replace the wire. • DF PWB (CN1) - DF relay PWB (YC3) • DF relay PWB (YC4) - BR PWB (YC5)
Problem description: The communication error was detected 10 times continuously
Step
Description
Causes
Measures
1
Firmware upgrade
The main unit firmware and the document processor firmware mismatch
Upgrade the main unit firmware and the document processor firmware to the latest version
2
Checking the connection
The connector is not connected properly, or the wire is faulty
Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP PWB (YC2) - Engine PWB (YC4)
Problem description: 1. The DP feed-shift motor home position cannot be detected even driving it for one round. 2. The DP feed-shift motor home position cannot be detected even after retrying the detection for 3 times
Step
Description
Causes
Measures
1
Checking the connection
The EEPROM is not properly installed
Reattach the EEPROM on the DP PWB
2
Replacing the DP feed-shift sensor
Replace the DP feed-shift sensor
3
Replacing the DP feed-shift motor
Replace the DP feed-shift motor
4
Replacing the DP PWB
The DP PWB is faulty
Replace the DP PWB
5
Replacing the engine PWB
The EEPROM is faulty
Replace the engine PWB
Repair of Kyocera ECOSYS M8124cidn MFP - Professional Troubleshooting Approach
The Kyocera ECOSYS M8124cidn multifunction printer (MFP) is a reliable office solution providing high-quality printing, scanning, and copying. However, even such durable equipment may eventually require professional repairs. We outline common issues with this model and explain why our company is the best choice for resolving them.
Common Kyocera ECOSYS M8124cidn Malfunctions
While built to last, the ECOSYS M8124cidn remains susceptible to wear. The most frequent issues include:
Paper Jams Caused by worn feed rollers, contaminated paper path, or sensor failures - one of the most workflow-disrupting issues.
Print Quality Issues Streaks, faded prints, or smudging often indicate worn drum units, developer assemblies, transfer belts, or fuser units.
System Errors Error codes like C7990 (waste toner overflow) or C6000 (fuser unit failure) require precise diagnostics and professional intervention.
Scanner/ADF Failures Paper pickup issues, skewing, or scanning failures typically stem from worn rollers or sensor malfunctions.
Network Issues Print/scan network errors often relate to faulty network modules or configuration errors.
These issues can halt office operations, making professional repair essential.
Why Choose Our Repair Service?
Our company offers professional ECOSYS M8124cidn repairs with distinct advantages:
Rapid Service Same-day on-site repairs minimize equipment downtime - most issues resolved at your location.
Genuine Parts We exclusively use original Kyocera components guaranteeing post-repair reliability.
Competitive Pricing Premium service at market-competitive rates - quality repairs without overpaying.
Service Warranty Comprehensive warranty covering both labor and installed components.
Full Support 24/7 consultation on device operation, configuration, and troubleshooting.
If your Kyocera ECOSYS M8124cidn malfunctions, avoid DIY attempts that might worsen problems. Our professional service restores your MFP to optimal condition, ensuring uninterrupted business operations through fast, guaranteed repairs.
Contact us today - entrust your equipment to professionals!